Transforming Technologies Continuous Workstation Monitors Model CM410 User's Manual

Transforming Technologies Continuous Workstation Monitors Model CM410 User's Manual

 

Ohm Metrics
Continuous Workstation Monitors Model CM410

Instruction Manual

 

CM410 Installation Diagrams

  1. Mount monitor under bench area (use included screws or Velcro).
  2. Attach the “Bench” cord (smaller plug) to the back of monitor and attach the banana plug into the common point ground.
  3. Plug AC power supply to monitor and grounded 110v outlet (monitor grounded through AC Adapter). Bench light should be green.
  4. Operator LED should be RED and alarm will sound 1 long
  5. With wrist strap worn correctly while plugged into monitor, LED will go from RED to GREEN when in use indicating grounding is functioning.

Operation

Monitoring begins when the coiled cord of the wrist strap is plugged into the monitor or remote jack. The status of a wrist strap resistance is indicated by a the bicolor LED and audi- ble Alarm:

Stand-by indication.

If the wrist strap is removed or not being worn but is still plugged into monitor, an audible alarm will sound for 4-6 seconds, and the “OP” (operator) led will be will be blink RED.

Normal indication.

For normal operating resistance “OPER”/”BENCH” led will

be GREEN.

High alarm.

If the operator wrist strap or worksurface mat’s resistance is higher than maximum, the corresponding led will turn RED and audible alarm will sound.

Calibration and Verification

The CM410 is factory calibrated and fixed. It does not re- quire re-calibration. It is recommended to verify proper op- eration with the CM410PV verification unit available from Transforming Technologies.

 

Product Specifications

Wrist strap open circuit voltage 0.7 VDC, +0.1VDC @ < 2mA
Alarm indicators Visual, audible
Alarm set point 38 to 87pF (human body); with1 meg ohm wrist strap resistance
Unit monitoring capabilities One person and one mat
Periodic Verification Units CM410PV: NIST Calibrated Periodic verification tool for CM410
Dimensions/Weight 1.00” H x 2.40” W x 2.40” D
(2.54 x 6.10 x 5.84 cm) 7.80 oz
Mounting Mounting materials included
Power Supply Input: 120VAC—60hz, Output: 12VDC, 200mA
Audible Alarm 10 beeps (max); 5 seconds
Adjustment No adjustments required

 

Service and Warranty

Transforming Technologies, LLC provides a limited warranty for the Model CM400, CM410 and CM420. All new products are guaranteed to be free from defects in material and workmanship for a period of one (1) year from the date of shipment. Liability is limited to servicing (after evaluating, repairing or replacing) any product returned to Transforming Technologies. The company does not warrant damage due to misuse, neglect, alteration or accident. In no event shall Transforming Technologies be liable for collat- eral or consequential damages. To receive service under warranty, please contact Transforming Technologies.